Logical drive is queued for rebuilding. [SOLVED] HP B120i Raid

Logical drive is queued for rebuilding Rating: 8,6/10 1410 reviews

Drive failure in a netware environment, Failed drives or interim recovery mode

logical drive is queued for rebuilding

This can be beneficial to other community members reading the thread. Select the member drive the source drive you want to replace with a larger one. If the wrong battery is installed, replace it with the correct one for your system or accept less than 72 hours of retention time 0x00010003 info ram, popup Battery capacity is normal Battery capacity is normal No action required 0x00010004 info ram, nvram, popup Battery is discharging Battery is re-conditioning No action is required 0x00010005 info ram, popup Battery is charging Battery is charging No action is required 0x00010006 info ram, popup Battery reconditioning is completed Battery reconditioning is completed No action is required. The number of logical drive s contained in this logical volume. Even if one hard drive or one logical drive fails, an exact replica still resides on other drives.

Next

HPE Support document

logical drive is queued for rebuilding

If necessary, temperature thresholds can be modified to suit different working conditions. The current logical volume configuration and status will be displayed on the Select one or more logical drive s available on the list. Spares automatically joins a logical drive when a drive fails. Terminal screens will be used in the configuration samples. See Logical Drive, Logical Volume, and Logical Partitions Listed below are the basics about configuring a logical drive for a redundant controller system: Redundant Controller 10.


Next

HP SmartArray Ready for Recovery but never rebuilds

logical drive is queued for rebuilding

I've seen enclosure serial numbers contain garbage. So the LogicalDisk performance counters for this disk are available again. If password has not yet been set, the controller will directly ask for the new password. Slot Number Drive Entry These two functions are reserved for Fault Bus configuration. We also moved all the drives on this array controller to another server before going with our image backup method so that we could be sure and rule out any server related hardware. You can also try just removing disk 2 and putting it back again hot but again backup first. The password can not be replaced unless a correct old password is provided.


Next

HPE Support document

logical drive is queued for rebuilding

The existing controller takes over the workload within a second. We ensure that the operating system sees the drive then use ReclaiMe File Recovery software to extract data from the drive. I've got the firmware flash for the raid card which I'll be using before I try to get the array to rebuild. The problem is a mismatch of firmware on drives and controller card. In any case, locate the faulty drive, replace it, and restore data from backup.


Next

HP Smart Array P410 & HP SAS expander card

logical drive is queued for rebuilding

Redundant Controller rolling firmware upgrade Redundant Controller firmware synchronization. To correct this problem, check the data and power connections to the physical drives or replace the failed drive. The current name will be displayed. The capacity of the added drive will appear as an unused partition. You can select the stripe size of each array logical drive during the initial configuration.

Next

Drives OK / Logical Drive is queued for rebuilding

logical drive is queued for rebuilding

Traffic Distribution and Failover Process The diagram below illustrates a four-channel configuration using channel 0 as the communications path. Unconfigured 4 Indicates that the logical drive is not configured. A list of available selections will appear. Alert What Power Supply Failure Detected. Move Your Career Forward with certification training in the latest technologies. I have seen this could be because the other drive also has issues. The existing controller is always the Primary controller regardless of its original status and any replacement combined afterwards will assume the role of the Secondary.

Next

cpqDaLogDrvStatus

logical drive is queued for rebuilding

These bad sectors were the reason for the read errors encountered during the rebuild process. Bottom line is should work, but then of course you would sat that of the Areca! If the online default mode is used, data can be written onto it and you may continue with array configuration, e. When background parity initialization completes, the performance of the logical drive will improve. Fortunately, the sectors that were deemed bad did not contain any valuable data. What to Check the enclosure ventilation condition. The logical drive is in the queue for expansion. All members will be involved during the rebuild process.

Next

[SOLVED] HP B120i Raid

logical drive is queued for rebuilding

Just wanted to send an update in case anyone else was experiencing this problem. A logical configuration of drives will appear to the host as a single capacity volume. Joining two controllers into a dual-active pair can eliminate most possible points of failure. Introduction Self-Monitoring, Analysis and Reporting Technology S. What to Check power supply condition, voltage threshold settings and contact the your system supplier.

Next